Specification |
Item | Specification |
Power supply (V) | 12 |
Output type | Combination of output signals |
гЂЂ | P | P-R | R | R-N | N | N-D | D |
Signal "1" | 12V | 12V | 0 | 0 | 0 | 0 | 0 |
Signal "2" | 0 | 12V | 12V | 12V | 0 | 0 | 0 |
Signal "3" | 0 | 0 | 0 | 12V | 12V | 12V | 0 |
Signal "4" | 0 | 0 | 0 | 0 | 0 | 12V | 12V |
Checking the power steering fluid level
With the vehicle on level ground, check the fluid level in the power steering
reservoir periodically. The fluid should be between MAX and MIN marks on the side
of the reservoir at the normal tem ...
CVVT Oil Control Valve (OCV) Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the OCV connector.
3.
Measure resistance between the OCV terminals 1 and 2.
4.
Check that the resistance is within the specifi ...