Kia Sedona: Blower Motor Repair procedures - Blower - Heating,Ventilation And Air Conditioning - Kia Sedona YP Service ManualKia Sedona: Blower Motor Repair procedures

Third generation YP (2014-2024) / Kia Sedona YP Service Manual / Heating,Ventilation And Air Conditioning / Blower / Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.
3.
Replace the blower motor if it is proved that there is a problem with it.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the blower motor connector (A).

4.
Remove the blower motor (A) after loosening the screws.

5.
Install in the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery/recycling/charging station. 3. When the engine is cool, drain the engine coolant fro ...

Blower Resistor (Manual) Repair procedures
Inspection 1. Measure the resistance between the terminals. 2. If the measured resistance is not within specification, the blower resistor must be replaced (after removing the resistor). Repl ...

Other Information:

Rear Door Power Window Regulator Repair procedures
Replacement 1. Remove the rear door window glass. (Refer to Rear Door - "Rear Door Window Glass") 2. Loosen the mounting nut and remove the rear door power window regulator connector (A). ...