Warning Lamp Activation |
Warning Lamp Behavior after Ignition On |
1. |
Active fault or historical fault counter is greater or equal to 10. |
2. |
Normal or historical fault counter is less than 10. |
3. |
When turning the ignition switch ON during variant coding
(EOL) mode, the airbag warning lamp illuminates and blinks at intervals
of 1 second till the coding is completed.
In case the variant coding has successfully completed, the
airbag warning lamp will turn on for 6 seconds and then off. Otherwise,
the airbag warning lamp will continuously blink at intervals of 1
second.
When there is active fault in airbag system or SRSCM internal
fault, the variant coding (EOL) can’t be completed. In this case,
perform the variant coding (EOL) procedure again after troubleshooting
with the GDS.
|
1. |
Loss of battery supply to the SRSCM : warning lamp turned on continuously. |
2. |
Loss of internal operating voltage : warning lamp turned on continuously. |
3. |
Loss of Microprocessor operation : warning lamp turned on continuously. |
4. |
SRSCM not connected : warning lamp turned on continuously. |
Field Effect Transistor (DATC) Repair procedures
Inspection
1.
Turn the ignition switch ON.
2.
Manually operate the control switch and measure the voltage of the blower motor.
3.
Operate the control switch to raise the voltage up to high ...
Accelerator Position Sensor (APS) Specifications
Specification
AcceleratorPositionOutput Voltage (V) [Ref=5V]APS1APS2C.T0.7 ~ 0.80.29 ~ 0.46W.O.T3.85 ~ 4.351.93 ~ 2.18
...