Kia Sedona: Line Pressure Control Solenoid Vale Schematic Diagrams - Automatic Transaxle Control System - Automatic Transaxle System - Kia Sedona YP Service ManualKia Sedona: Line Pressure Control Solenoid Vale Schematic Diagrams

Third generation YP (2014-2025) / Kia Sedona YP Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Line Pressure Control Solenoid Vale Schematic Diagrams

Circuit Diagram

Line Pressure Control Solenoid Vale Description and Operation
Description • Line pressure control solenoid valve is a Variable Force Solenoid (VFS) type. • When TCM supplies variable current to solenoid valve, line pressure is controlled ...

Line Pressure Control Solenoid Vale Repair procedures
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A). 4. Me ...

Other Information:

Smart Cruise Control Switch Schematic Diagrams
Circuit Diagram ...

Description and Operation
Warning Lamp Activation Warning Lamp Behavior after Ignition On As soon as the operating voltage is applied to the SRSCM ignition input, the SRSCM activates the warning lamp for a lamp check. T ...