Inspection |
1. |
Turn the ignition switch OFF. |
2. |
Disconnect the PCSV connector. |
3. |
Measure resistance between the PCSV terminals 1 and 2. |
4. |
Check that the resistance is within the specification.
|
Removal |
1. |
Turn the ignition switch OFF and disconnect the battery negative (-) terminal. |
2. |
Disconnect the purge control solenoid valve connector (A). |
3. |
Disconnect the vapor hoses (B) from the purge control solenoid valve. |
4. |
Remove the valve from the bracket. |
Installation |
|
1. |
Install in the reverse order of removal.
|
Automatic climate control system
1. Turn the ignition switch to the ON position.
2. Select the defroster position pressing the defroster button ().
3. While pressing the air conditioning button (A/C), press the air intake control ...
SS-A Solenoid Valve(ON/OFF) Components and Components Location
Components Location