Kia Sedona: Line Pressure Control Solenoid Vale Components and Components Location - Automatic Transaxle Control System - Automatic Transaxle System - Kia Sedona YP Service ManualKia Sedona: Line Pressure Control Solenoid Vale Components and Components Location

Third generation YP (2014-2025) / Kia Sedona YP Service Manual / Automatic Transaxle System / Automatic Transaxle Control System / Line Pressure Control Solenoid Vale Components and Components Location

Component Location

1. Line pressure control solenoid valve (LINE_VFS)
Line Pressure Control Solenoid Vale Specifications
Specification Item SpecificationControl typeN/H (Normal High)Control pressure kpa (kgf/cm², psi)500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)Current value (mA) 50 ~ 850Coil resistance(Ω)5.1 ± 0.3 ...

Line Pressure Control Solenoid Vale Description and Operation
Description • Line pressure control solenoid valve is a Variable Force Solenoid (VFS) type. • When TCM supplies variable current to solenoid valve, line pressure is controlled ...

Other Information:

Opening the hood
1. Pull the release lever to unlatch the hood. The hood should pop open slightly. Open the hood after turning off the engine on a flat surface, shifting the shift lever to the P (Park) position a ...

SCC will be temporarily canceled when
Cancelled manually The brake pedal is depressed. Press the CANCEL button. The SCC turns off temporarily when the indicator on the LCD display turns off. The CRUISE indicator is illuminated ...