Components Location |
Canister Close Valve (CCV) Specifications
Specification
ItemSpecificationCoil Resistance (Ω)19.5 ~ 22.5 [20°C(68°F)]Rated Voltage (V)12Operation Voltage (V)9 ~ 16Operation Release Voltage (V)Below 6
...
Cruise Control Switch Repair procedures
Inspection
Measuring Resistance
1.
Disconnect the cruise control switch connector from the control switch.
2.
Measure the resistance between terminals on the control switch when each funct ...