Kia Sedona: Specifications - AC Inverter System - Body Electrical System - Kia Sedona YP Service ManualKia Sedona: Specifications

Third generation YP (2014-2024) / Kia Sedona YP Service Manual / Body Electrical System / AC Inverter System / Specifications

Specification
Item
Specification
Rated Voltage
DC 12.5V
Operating voltage
DC 12.2 ~ 15.3V
Operating temperature
-40°C ~ 75°C
Output voltage
AC 198 ~ 242V (rms)
Output frequency
60 ± 6 Hz
Rated power
200W (-30°C ~ 45°C)
Current spec.
Full load input current : Max. 20A
Key OFF current : Max 1㎂

AC Inverter System
...

Components and Components Location
Component Location 1. Battery2. AC inverter switch3. AC inverter unit4. AC inverter outlet ...

Other Information:

Fuel Tank Pressure Sensor (FTPS) Repair procedures
Inspection 1. Connect the GDS to the Data Link Connector (DLC). 2. Measure the output voltage of the FTPS. Pressure [kPa (kgf/cm², psi)]Output Voltage (V) [Ref=5V]-6.67 (-0.06, -0.97)0.502 ...

Intake Air Temperature Sensor (IATS) Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the IATS connector. 3. Measure resistance between the IATS terminals 3 and 4. 4. Check that the resistance is within the speci ...