Replacement |
1. |
Disconnect the stopper (B) from the glove box (A). |
2. |
Disconnect the air damper (A) from the glove box (B). |
3. |
Remove the filter cover (A) by pressing the knob. |
4. |
Replace the air filter (A) with a new one according to the direction of air filter.
|
5. |
Install in the reverse order of removal. |
Compressor oil Repair procedures
Oil Specification
1.
The HFC-134a system requires synthetic (PAG) compressor oil
whereas the R-12 system requires mineral compressor oil. The two oils
must never be mixed.
2.
Compressor (P ...
Components and Components Location
Component Location
1. Horn switch2. Horn relay (Built-in Metal Core Block PCB)3. Horn (Low pitch)4. Horn (High pitch)5. Clock spring
...