Specifications |
Item | Specification |
Fan type | PULLER |
Fan speed control | Resistor |
Air flow rate [㎥/h (yd³/h)] | 2,650 (3,466) - 8% min. |
Fan speed (rpm) | 1,980 ± 8% |
Current (A) | 23.3 + 10% max. |
Auto Head lamp leveling Unit Troubleshooting
Inspection with GDS
Initialization and diagnosis sequence by using GDS equipment.
The content below summarizes the procedure for A/S using GDS.
No.Procedure1Locate vehicle to flat plane2Tire ch ...
Rear Blower Motor Repair procedures
Inspection
1.
Connect the battery voltage and check the blower motor rotation.
2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper oper ...