Kia Sedona: Starter Specifications - Starting System - Engine Electrical System - Kia Sedona YP Service ManualKia Sedona: Starter Specifications

Third generation YP (2014-2025) / Kia Sedona YP Service Manual / Engine Electrical System / Starting System / Starter Specifications

Specification
Starter
Item
Specification
Rated voltage
12 V, 1.7 kW
The number of pinion teeth
12
Performance
[No-load, 11.5 V]
Ampere
Max.85 A
Speed
Min. 2,550 rpm

Troubleshooting
Troubleshooting     • The battery must be in good condition and fully charged for this troubleshooting. ...

Starter Components and Components Location
Components 1. Front bracket assembly2. Clutch set assembly3. Lever4. Lever packing5. Magnetic switch assembly6. Through bolt7. Planet gear 8. Shield9. Armature assembly10. Yoke assembly11. Brush ...

Other Information:

Checking the amount of air conditioner refrigerant and compressor lubricant
When the amount of refrigerant is low, the performance of the air conditioning is reduced. Overfilling also has a negative impact on the air conditioning system. Therefore, if abnormal operation is ...

Heated Steering wheel Repair procedures
Inspection 1. Measure the resistance of NTC and Heated pad. – NTC resistance : 3.42 ~ 4.18 kΩ (Standard : 25°C) – Heated pad resistance : 1.5 ~ 1.9 Ω (Standard : 19 ~ 2 ...

Categories