Kia Sedona: Blower Resistor (Manual) Repair procedures - Blower - Heating,Ventilation And Air Conditioning - Kia Sedona YP Service ManualKia Sedona: Blower Resistor (Manual) Repair procedures

Third generation YP (2014-2024) / Kia Sedona YP Service Manual / Heating,Ventilation And Air Conditioning / Blower / Blower Resistor (Manual) Repair procedures

Inspection
1.
Measure the resistance between the terminals.
2.
If the measured resistance is not within specification, the blower resistor must be replaced (after removing the resistor).

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

4.
Install in the reverse order of removal.
Blower Motor Repair procedures
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substitute with a known-good blower motor and check for proper oper ...

Field Effect Transistor (DATC) Repair procedures
Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and measure the voltage of the blower motor. 3. Operate the control switch to raise the voltage up to high ...

Other Information:

Tilting the sunroof (for front sunroof)
To open the sunroof, push the sunroof control lever upward until the sunroof moves to the desired position. To close the sunroof, push the sunroof lever forward or pull downward until the sunro ...

Don't neglect the interior
Moisture can collect under the floor mats and carpeting and cause corrosion. Check under the mats periodically to be sure the carpeting is dry. Use particular care if you carry fertilizers, cleani ...