Kia Sedona: Blower Resistor (Manual) Repair procedures - Blower - Heating,Ventilation And Air Conditioning - Kia Sedona YP Service ManualKia Sedona: Blower Resistor (Manual) Repair procedures

Third generation YP (2014-2024) / Kia Sedona YP Service Manual / Heating,Ventilation And Air Conditioning / Blower / Blower Resistor (Manual) Repair procedures

Inspection
1.
Measure the resistance between the terminals.
2.
If the measured resistance is not within specification, the blower resistor must be replaced (after removing the resistor).

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Disconnect the connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

4.
Install in the reverse order of removal.
Blower Motor Repair procedures
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substitute with a known-good blower motor and check for proper oper ...

Field Effect Transistor (DATC) Repair procedures
Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and measure the voltage of the blower motor. 3. Operate the control switch to raise the voltage up to high ...

Other Information:

Brake Line Repair procedures
Removal 1. Disconnect the brake fiuid level switch connector, and remove the reservoir cap. 2. Remove the brake fluid from the master cylinder reservior with a syringe.   &nb ...

Headlamp (bulb type) -high/low
1. Open the hood. 2. Remove the front cover(1) and headlamp assembly nuts(2). 3. Remove the headlamp assembly from the body of the vehicle 4. Remove the headlamp bulb cover by turning it counte ...

Categories


Copyright В© www.kisedona.com 2016-2024