Oil Level Gauge & Pipe Repair procedures
Removal and Installation
1.
Remove the oil level gauge rod (A) and the oil level gauge (B).
Tightening torque:
18.6 ~ 22.6 N.m (1.9 ~ 2.3 kgf.m, 13.7 ~ 16.6 lb-ft)
...
Rear Glass Defogger Printed Heater Repair procedures
Inspection
Wrap tin foil around the end of the voltmeter test lead to
prevent damaging the heater line. Apply finger pressure on the tin foil,